Jeddah - Al Aziziyah - 60th Street - Al Malika Commercial Administrative Center05997782860508163591
AREN

From the main unit to pumps, valves and balancing

Chiller Installation and Maintenance

Integrated chiller replacement, installation and maintenance covering chilled-water networks, pumps, controls, insulation, cleaning and commissioning.

Air-cooled chiller and chilled-water network

Chiller solutions for large buildings and facilities

A chiller plant includes more than the main machine. Pumps, valves, strainers, expansion provisions, air separation, chilled-water piping, air-handling units, controls, insulation and balancing all affect the final performance.

We assess the operating condition and network before recommending repair, replacement or modification. The scope may include lifting coordination, mechanical connections, supports, pressure testing, flushing, insulation, BMS interfaces and commissioning.

Chiller services

  • Air-cooled chiller installation or replacement
  • Chilled-water piping modification and installation
  • Pumps, valves, strainers and air-separation components
  • Pipe insulation, cladding and structural supports
  • Chemical cleaning and flushing when technically required
  • Flow switches, sensors, controls and BMS coordination
  • Commissioning and chilled-water TAB coordination

Information required for an initial study

  • Chiller model, capacity and equipment data
  • Chilled-water piping drawings
  • Available temperature, pressure and flow readings
  • Pump, valve and AHU schedules
  • Maintenance and fault history
  • Lifting access and planned shutdown windows

Service delivery stages

  1. Existing-system assessmentInspect the chiller, network, pumps and controls and identify the real constraint.
  2. Replacement or repair planDefine equipment, valves, connections, shutdown sequence and safety requirements.
  3. Installation and testingExecute piping, supports, pressure testing, flushing, insulation and connections.
  4. Commissioning and balancingStart pumps and chillers, adjust flows and document operating readings.

Evaluate the complete chilled-water system

Poor cooling may be caused by low flow, air in the network, fouled heat exchangers, valve issues or unsuitable pumps rather than the chiller alone. Decisions should be based on measured system conditions.

  • Check supply and return temperature difference
  • Verify pump duty, valve direction and strainers
  • Inspect insulation, condensation and pipe supports
  • Provide measuring, drain and vent points
Chiller contractorChilled-water pipingPumps and BMS

Sectors we serve

Chillers are commonly evaluated for large or long-operating facilities that need centralized chilled-water distribution.

Hospitals and medical facilitiesHotels and large complexesMalls and commercial buildingsFactories and industrial facilitiesGovernment and education buildingsAirports and major infrastructure

Why New AlFouz AC?

Experience with existing-equipment replacementCoordinated shutdown, lifting and start-upFlow and balancing considered with equipmentDocumented valves, insulation and testing scope

Related HVAC services

Chiller efficiency depends on piping, balancing and maintenance. Review the connected services.

Frequently asked questions

When is chiller replacement better than repair?

The decision follows an assessment of compressors, heat exchangers, controls, spare-parts availability, energy use, repair cost, remaining life and current cooling demand.

Can the scope include pumps and valves?

Yes. The agreed scope may include pumps, isolation and balancing valves, strainers, air separators, expansion components, supports and insulation.

When is chemical cleaning required?

It may be considered when deposits, contamination or poor heat transfer are confirmed. The chemical and procedure must suit the piping and connected equipment.

Why is water balancing required after modifications?

Balancing verifies that each branch and terminal receives its required design flow and prevents excessive or insufficient flow that reduces performance.

Do you have an existing chiller or replacement project?

Send equipment data, drawings, photos and available readings to define the initial assessment scope.

Request a system review
Project coverage

Chiller and chilled-water projects

We support projects in Jeddah, Makkah Region and other Saudi cities according to project scope, size and mobilization requirements, without duplicating near-identical city-service pages.